Qualification of Inspectors for visual inspection (Knapp Test)


2.0      Scope: Final visual inspection is performed manually by human operators. 
 Prior to being qualified as an inspector, each inspector must be successfully trained and qualified per this procedure.
Qualification Criteria
  • Inspectors are qualified if their detection of rejects is ≥ 70% detection of known rejects and ≤ 30% of blanks (false reject) in any given test set.
  • The inspector must meet this requirement three (3) times before being considered a qualified manual visual inspector
Re-Qualification Schedule
  1.  Visual inspectors are re-qualified annually.
  2. If inspection performance declines, re-qualification may be required in shorter time-frames.
  3. Annual eye sight exams at optometrist for visual acuity with 20/20 vision or 20/20 corrected. If eyesight is corrected with eye glasses or contact lenses, then those must be worn during the product inspection process.
References:.
1.    USP , Injections and Implanted Drug Products (Parenterals) – Product Quality Tests
2.    USP Visible Particulates in Injections 3.    USP Visual Inspection of Injections
Responsibilities:
  1. It is the responsibility of the Production Manager/Production Officer to ensure that visual inspectors are qualified  per this SOP.
  2. It is the responsibility of the Quality Assurance (QA) to perform investigations of inspectors who do not meet requalification requirements.
Procedure:
A. The inspection process is designed to ensure that 100% of every container
Of every lot of parenteral preparations is “essentially free” from visible particulates.
 1. Different test sets needed for each drug product category.
  • Clear Liquid
  • Suspension
  • Others
2.  Test sets can be made up of production rejects or created manually with
Characterized particulate material.  Test sets are made up of
blank ampoules,Ampoules with particles/fiber Misprinted Sealing defect
3. Test sets are labeled so as to keep the identity of the rejects unknown to the trainee.
4. Units that are no longer usable in a test set due to breakage, particle no longer detectable; cake breakage, etc. will be replaced.
B. . Qualify an inspector using a test set that is representative of the product to be inspected.  For example, if the product to be inspected contains gel, qualify the inspector using the test set containing gel
1. Inspectors are qualified if their detection of rejects is ≥ 70% detection of known rejects and ≤ 30% of blanks (false reject) in any given test set.  . The inspector must meet this requirement three (3) times before being considered a qualified manual visual inspector.
2. The trainee is trained on the operation of the manual inspection booth.
3. The trainee is shown the rejects within the test set to be trained upon.
Each of the rejects is described as the trainee inspects the rejects within the test  set. A blank is also given for inspection as well.
4. Ensure that operators spend appropriate time (5+ seconds against each
colored background) with each product container during the visual inspection process
5. The reject vials are then mixed in with the rest of the test set and the trainee inspects each vial while being observed by the trainer.  The trainee inspects all of the vials and notes the defect code for the reject vials while maintaining separation of the rejects and the blanks.
6. Upon completion the trainer compares the trainee’s determinations to the
actual defects/blanks. ≥ 70% detection of known rejects and ≤ 30% of blanks (false reject) is required to pass.  The trainee repeats the inspection process until successfully passing three (3) times
Inspector Re-Qualification Schedule:
1.Visual inspectors are re-qualified annually.
2.If inspection performance declines, re-qualification may be required in shorter time-frames.
3.Common causes of declined performance that may lead to a need for re-
qualification include fatigue, demonstration of an improper reject rate during operations, etc. and/or causing excessive product investigations.
4. Annual eye sight exams at optometrist for visual acuity with 20/20 vision or 20/20 corrected.  If eyesight is corrected with eye glasses or contact lenses, then those must be worn during the product inspection process.

20 comments:

  1. If there operator, done the test 3 time
    And results, 1st run 75, second run 70
    Third run, 65%
    What is the final result, is this operator qualified for visual inspection test

    2nd q, the 3 times in 3 different days
    N there same day, to include factorr fatigue

    ReplyDelete
  2. No ,each run required within critaria

    ReplyDelete
  3. What is the responsibility of the company to provide vials that are clear and in decent condition for the inspector to see flaws and rejects?

    ReplyDelete
  4. So how many vials should be tested? Wanna know the total quantity of samples should be tested.

    ReplyDelete
  5. So how many vials should be tested? Wanna know the total quantity of samples should be tested.

    ReplyDelete
  6. Can we apply this procedure for solid dosage form or is there any other inspector qualifications procedure

    ReplyDelete
  7. National Forensic Sciences University, R&D department provides Visual Inspection Kits and also exporting to my US FDA approved plants.

    ReplyDelete
  8. National Forensic Sciences University, R&D department provides Visual Inspection Kits and also exporting to my US FDA approved plants.

    ReplyDelete
  9. Today, I was just browsing along and came upon your blog. Just wanted to say good blog and this article helped me a lot, due to which I have found exactly I was looking. buy Anabol 10mg online

    ReplyDelete
  10. You share informative post related to visual inspection Knapp test. This post is very helpful for us. I learn more through this post. Further, The garage door repair Woodstock GA provide the quality work under the expert team.

    ReplyDelete
  11. Your information related to visual inspection is amazing. Also, we have years of experience with Inflatables Rental Services in San Diego CA and have managed many events. We can bring happiness to your events.

    ReplyDelete
  12. Hey friend, it is very well written article, thank you for the valuable and useful information you provide in this post. Keep up the good work! FYI, Pet Care adda
    can i use flipkart axis bank credit card anywhere, The Anthropocene Reviewed PDF Free Download,Essay on Women Empowerment in English

    ReplyDelete
  13. Thanks & Regards from FTI Incorporation

    Keep providing such complete & informative content via your blog & motivating us this is a great opportunity for us to enhance our knowledge with the help of your content.

    ReplyDelete
  14. Anabolic-androgenic steroids (AAS): These are synthetic derivatives of testosterone. While they have legitimate pharmaqo labs medical uses, they are also misused for performance enhancement in sports and bodybuilding.

    ReplyDelete
  15. Jig and fixture design plays a crucial role in manufacturing by ensuring precision, efficiency, and consistency. These tools are tailored to hold workpieces in place, improving productivity and product quality. jig and fixture design

    ReplyDelete
  16. Ankara'da doğal taş Kilitli parke taşı fiyatları hakkında bilgiye ihtiyacım var.

    ReplyDelete
  17. The FESCO (Faisalabad Electric Supply Company) rate per unit varies depending on the number of units consumed per month and the tariff category (residential, commercial, industrial, etc.).

    For residential consumers in April 2025, the per-unit rates are approximately:

    1-100 units: PKR 22
    101-200 units: PKR 32
    201-300 units: PKR 37
    301-400 units: PKR 43
    401-500 units: PKR 47
    501-600 units: PKR 49
    601-700 units: PKR 52
    Above 700 units: PKR 65
    These rates are subject to change and do not include other charges like fixed charges, taxes (GST, Electricity Duty), Fuel Price Adjustment (FPA), and other surcharges that are part of the total bill.
    fesco rate per unit

    ReplyDelete
  18. Nice post.You can get your dupplicate electricity bill by visiting https://fescobill.pk/

    ReplyDelete

Contact

Name

Email *

Message *

Popular Posts